故障现象
笔者某次配置了一个16日的AM模块 。出现了一个希奇的问题 。配置好后,拨入时没有Modem拨号声 。只有电话的声 。并且音指示灯也不亮 。当笔者拔下模块上的电话线时 。指示灯亮了 。
[b]配置[/b]
620#sh run
Building configuration...
Current configuration : 866 bytes
!
version 12.2
service timestamps debug uptime
service timestamps Jog uptime
no service passWord-encryption
!
hostname2620
enable secret 5 $1$pUrf$9xGOg.zyxKawi9NljLHHr1
usernameuser password 0 Cisco
ip subnet-zero
!
!
no ip domain-lookup
!
!
!
!
interface FastEthernet0/0
ip address 136.0.0.254255.255.0.0
duplex auto
speed auto
!
interface Group-Async1
ip unnumbered FastEthernet0/0
encapsulation ppp
async default routing
async mode interactive
peer default ip address pool lab
ppp authentication chap
group-range 33 48
!
!
ip classless
no ip http server
ip pim bidir-enable
!
!
line con 0
password cisco
line 33 48
login local
modem InOut
autocommand ppp
transport input all
autoselect ppp
stopbits 1
flowcontrol hardware
line aux0
line vty 0 4
password Cisco
login
!
no scheduler allocate
end
诊断过程
笔者仔细检查配置文件,发现缺少ip pool,加上ip local pool lab(start ip addr)(stop ip addr),没有效果 。后来笔者想到拨号采用的都是模拟信号,与接地有很大关系 。没自动应答:多半是接地问题 。所以直接把路由器上的接地螺钉,用一根导线接到防静电地板下面的铁支柱上,问题解决了 。
排除心得
路由器标准接地的方法是在铺设电源线的时候放置一根地线,然后路由器的外壳接到地线上去就好?,笔者估计原来负责网络系统搭建的厂商采用的电源线忽略了地线,否则也不会出现这样的问舰 。接路由器电源的时候假如有地线,一般不需要我们再接地了 。
推荐阅读
- 上 思科路由器系列软件安装与升级步骤
- Cisco 12000系列千兆比特交换路由器
- Cisco Catalyst 6500系列交换机和Cisco 7600系列互联网路由器
- 创见推出思科2600系列路由器专用内存
- 匪夷所思 100元搞定校园网宽带路由器
- Corega公司的94Mbps有线宽带路由器
- 火车晚点未定会停运吗
- 工作更得力!SOHO宽带路由器选购参考书
- 详细讲解Cisco 路由器防止DDos攻击