slotclass idtype idhardware verfirmware version
slot 0main boardMB_M8241_26901.001.00
slot 3ether cardNM_2FE1.001.00
slot 4sync cardNM_2HS1.001.00
5、设备软件版本已是最新 , 对该版本TAC中心没有通告过类似故障情况 。
批注:根据分段排查原则 , 在确认内网正常后 , 对出口问题排查路由器工作状态 。对于掉线类型的故障 , 确定路由器设备配置正确的同时 , 也要确定CPU利用率是否过高 。此外我们建议确保设备软件版本是我司发布的最新相应版本 , 软件版本可以登陆锐捷网站下载 。6、故障发生时,SH 路由器串口信息:
Red-Giant#shinterface serial 4/1
serial 4/1 is UP, line protocol is DOWN
Hardware is Infineon DSCC4 PEB20534 H-10 serial
Description: jianyang
Interface address is: 192.168.8.34/30
MTU 1500 bytes, BW 2000 Kbit
Encapsulation protocol is PPP, loopback not set, but seems as if in loopback state.
Keepalive interval is 200 sec , set
Carrier delay is 2 sec
RXload is 11 ,Txload is 2
LCP Acksent
Closed: ipcp
Queueing strategy: WFQ
5 minutes input rate 90808 bits/sec, 32 packets/sec
5 minutes output rate 22092 bits/sec, 33 packets/sec
343821 packets input, 129308802 bytes, 0 res lack, 0 no buffer,3 dropped
Received 1 broadcasts, 0 runts, 0 giants
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 abort
339962 packets output, 27542504 bytes, 0 underruns,14 dropped
0 output errors, 0 collisions, 2 interface resets
3 carrier transitions
V35 DTE cable
DCD=upDSR=upDTR=upRTS=upCTS=up
从标红部分我们可用看出,物理线路正常,问题出在LCP协商上 , 接口状态提示有环路 。批注:根据分段排查的原则 , 我们可以通过SH INTERFACE命令 , 确认故障发生时 , 路由器外网端口是否正常转发数据 。7、电信工程师配合将光猫到局端打环测试,发现光猫设备存在问题,电信将两端光猫更换,但测试发现故障依然存在 。
批注:根据分段排查的原则 , 确认广域网线路是否存在传输问题 。8、使用DEBUG命令跟踪分析PPP:
Red-Giant#debug ppp error
PPP: serial 4/0 rcvd id 106 didn't match sentid 109 ,dropping packet, state=Acksent
bu
PPP:serial 4/0 state is FSM_TERMSENT ,dropping packet
PPP: serial 4/0 rcvd id 107 didn't match sentid 110 ,dropping packet, state=Termsent
PPP:serial 4/0 state is FSM_TERMSENT ,dropping packet
PPP: serial 4/0 rcvd id 108 didn't match sentid 111 ,dropping packet, state=Termsent
PPP:serial 4/0 state is FSM_TERMSENT ,dropping packet
PPP: serial 4/0 rcvd id 109 didn't match sentid 112 ,dropping packet, state=Termsent
PPP: serial 4/0 rcvd id 110 didn't match sentid 113 ,dropping packet, state=Acksent
PPP: serial 4/0 rcvd id 111 didn't match sentid 113 ,dropping packet, state=Acksent
PPP: serial 4/0 rcvd id 112 didn't match sentid 113 ,dropping packet, state=Acksent
PPP: serial 4/0 LCP appears to be looped back.
PPP: serial 4/0 LCP appears to be looped back.
在sh interface serial 4/1
输出中LCP协商一直为Acksent的原因找到,继续分析 , 网络使用一段时间后 , 会rcvd id 与 sentid 号出现不一致现象 。向TAC中心反馈该情况后 , 初步判定问题可能是因为G/V转换器处理异常造成(此部分只能根据获取的DEBUG信息估计 , 协议转换器的内部具体情况 , 我们不了解) 。